9

Starting the boiler

Warning: Putting the boiler into
operation and its first start-up must
be produced only by certified

by Protherm specialist
specialized organization!

When starting the boiler for the first time, make sure
is that:

1. the boiler is connected to electrical network And

in this case, the phase and zero are not mixed up.

2. gas shut-off valve is open;
3. service taps for heating and hot water supply

4. The pressure in the heating system is

within acceptable limits 1 - 2 bar.
Install the main switch (Fig. 1,
pos. 7) to the ON position (I). Boiler
will turn on and start working in mode
heating water in the boiler (if the boiler
connected to the boiler). After heating the water in
boiler the boiler will switch to mode
heating (provided that the mode
heating active). In case of protective

boiler shutdown on the panel display
control, a message will appear indicating
malfunction (see “Messages about
errors“, page 8). Using a button
RESET (Fig. 1, item 6) unlock
boiler. If, after switching on, the protective
shutdown will occur again or is not possible
will unlock the boiler,
contact your service organization.

Boiler shutdown

When the boiler is switched off for a short time
install the main switch (Fig.
1, pos. 7) to the OFF position (O).
When the boiler is turned off for a long time
period it is necessary to disconnect it from
electrical network and shut off the supply
gas to the boiler. If in winter period boiler
not used, then the heating system
needs to be emptied. However
Frequent draining should be avoided and
top-up of the heating system to avoid
formation of scale and deposits inside
boiler

Starting and shutting down the boiler

Boiler adjustment

Operating a boiler without room
regulator


according to the readings of the boiler sensor. IN
terminal block XT5 on terminals 5 and 6 is
jumper (factory setting). Order
settings:

Turn on the boiler with the main switch;
set the required temperature

flow line on the control panel.

Operating a boiler with room temperature
thermostat

IN this mode boiler supports
set temperature in the heating system
by room regulator. Jumper,
installed in the XT5 terminal block on clamps
5 and 6, removed. In its place is connected
room regulator. If indoors
with room regulator on radiators
thermostatic valves installed,
it is necessary to convert them completely
open position.
Warning: On the control panel

Meaning

Malfunction on-
outdoor sensor
temperature

The boiler operates without restrictions, but the temperature

The coolant is regulated by the boiler sensor (see.
“Setting the heating temperature”, page 5).

If the boiler does not operate in equithermal mode, then
such a message cannot appear.

__________________________________________________________________________

Installation, connection and startup of the Proterm Panther boiler

Mounted gas boiler Proterm Panther 25 KTV with forced exhaust of combustion products and model 25 KOV with natural exhaust, operating on natural gas or propane, are intended for heating and hot water supply country houses, cottages, small garden buildings, communal buildings and other objects that are equipped with a heating system with forced circulation of coolant and running water.

Fig.1. Mounted gas boiler 25 KTV PANTHER

1 – closed (sealed) combustion chamber (turbochamber); 2 - atmospheric burner; 3 - heat exchanger; 4 - circulation pump; 5 - air vent; 6 - heat exchanger of the DHW system; 7 - three-way valve drive; 8 - gas valve; 9 - ignition electrodes; 10 - control electrode; 11 - ignition unit; 12 - control panel; 13 - heating temperature sensor; 14 - emergency temperature sensor; 15 - traction sensor; 16 – fan; 17 – water pressure sensor

The boiler is designed to operate in a temperature range from +5 to 40 °C and relative humidity up to 85%.

The temperature of the external surfaces of the boiler unit (side and top cover) during boiler operation should not exceed the ambient air temperature by no more than 50°C.

When placing the boiler, it is not allowed to place objects near it:

From flame-resistant materials - at a distance of less than 100 mm from the surface;

Made from flammable materials, such as fibreboards, polyurethane, lightweight PVC, synthetic fibers, rubber, etc. - at a distance of less than 200 mm from the surface.

It is necessary to leave a free space of at least 1 m in front of the boiler to carry out maintenance work.

At the boiler Protherm Panther 25 KTV, the removal of combustion products and the supply of air for combustion is carried out by a special coaxial pipeline or separate pipelines.

From standard parts you can create a coaxial chimney for almost all installation options. The length of the chimney, type and number of sections must be agreed with the service organization.

The chimney must be laid in such a way that condensate from combustion products can be removed. For this purpose, there are special sections that are built into the chimney route.

The gas boiler Proterm Panther 25 KOV is designed to discharge combustion products into a chimney with natural draft. The boiler is connected to the chimney using a pipe with a diameter corresponding to the size of the chimney pipe.

It is not allowed to install objects into the pipe that restrict the passage of combustion products (for example, different kinds heat exchangers-heat recuperators, etc.).

Installation gas boiler Proterm Panther

The Protherm Panther 25 KTV (KOV) boiler should be installed in closed heating systems with water as the coolant. The nominal diameter of the system pipes is selected based on the characteristics of the pump. The piping is designed according to the required capacity of a given system, and not the maximum
boiler heating capacity.

In this case, the coolant flow should be such that the temperature difference between the supply and return is no more than 20 °C. The minimum water flow in the system is 500 l/hour. The piping system must be designed to ensure that air is removed from it.

Air vents are located at the highest place in the system and on all radiators. The heating system is filled to a pressure of at least 1 bar. The recommended pressure range in the system is 1.2 – 2 Bar.

Expansion tank The boiler is designed for a heating system capacity of 95 liters. In larger systems, another membrane-type expansion tank should be installed. Heating radiators can be equipped with thermostatic valves.

If the unit is controlled by a room regulator, the thermostatic valves are not installed in the room where the room regulator is located. The system must be thoroughly cleaned before installation.

DHW system

Water pressure in DHW system should be in the range 1 - 6 Bar. If the pressure exceeds 6 bar, a pressure reducing valve must be installed at the inlet. At high hardness tap water it is recommended to take appropriate measures to reduce it.

The connecting pipes have external threads. They must not be loaded with the weight of pipes from the heating system, hot water supply system or gas supply. It is necessary to strictly observe the installation dimensions of the connecting pipes (height, distance from the wall and between individual inlets and outlets).

At the bottom of the boiler there is a hydraulic group, which is equipped with a safety relief valve, a system filling (priming) valve and a drain valve. If exceeded maximum pressure in the system (2.5 kgf/cm2), water may flow out of the safety-relief valve or steam may escape.

It is recommended to connect the boiler to the heating system in such a way that during its repair it is possible to drain water only from the unit. The heating system can be replenished (in small quantities) using a refill tap.

The drain valve is designed to reduce the water pressure in the boiler during possible repairs. This tap can only partially drain the water from the boiler. Complete drainage of water or the entire heating system, as well as refilling, must be carried out using fill and drain valves (plugs) installed in
certain areas of the heating system.

Filling the Protherm Panther boiler and the system with water should be done in the following order:

Check that the pressure in the DHW system is higher than the water pressure in the heating system.

Carefully open the filling valve in the hydraulic group and at the same time monitor the pressure increase on the boiler pressure gauge. The tap opens by turning it counterclockwise, and turning it clockwise closes it.

Upon reaching required pressure The filling tap must be carefully closed and checked to see if the water pressure increases (the tap must be completely closed).

If the DHW pressure in the water supply is the same or lower than the pressure in the heating system, water may leak into the water supply, which is unacceptable. This can be prevented by setting check valve on the water supply pipe to the boiler.

During repairs, unfavorable building layouts, etc., you can connect the boiler to the heating system, DHW system and gas supply with special flexible hoses.

When using flexible hoses, they must have a length of no more than 0.5 m, protected from mechanical stress and damage, and exposure to aggressive substances. At the end of their service life, the hoses must be replaced with new ones. To connect the boiler to a pipeline made of copper pipes you can use a special connecting set of shaped copper pipes with fittings.

Tube sizes:

OB inlet and outlet – tube diameter 22 mm.
- DHW inlet and outlet – tube diameter 15 mm.
- Gas connection – tube diameter 22 mm.
- Connection safety valve– tube diameter 22 mm.

Gas connection

Size 25 KTV (KOV) - ZP is designed to operate on natural gas with a nominal pressure in the distribution network of 1.8 kPa, and a calorific value of 35900 kJ/m3. Pipe diameter, fittings and gas meter must be selected taking into account other gas appliances of the consumer. It is necessary to connect a pipe to the boiler with a minimum connecting diameter of 1/2“, but it is better with a nominal diameter of 3/4“.

Size 25 KTV (KOV) - P is designed to operate on liquefied gas (propane), with a calorific value of 12.3 to 13.0 kWh/kg.

Due to the fact that the operation of a boiler using cylinders is problematic, first of all, from the point of view of ensuring a sufficient number of them, as well as their further use, it is planned to simultaneously use a gas tank near the heated object and fill it with an authorized organization.

Calculations required sizes supplying propane from a gas tank to a boiler unit or to other gas appliances are part of the design and delivery of the gas tank. Using a gas pressure reducing valve, it is necessary to ensure a nominal gas pressure in front of the boiler of 3.0 kPa.

Air supply and combustion products exhaust

Is air supplied and combustion products removed through an external coaxial pipeline? 100 mm. Equivalent pipeline length (numerically equal to the sum linear meters straight pipe and the number of elbows 90°) should be no more than 9 m. For an equivalent pipeline length of more than 3 m, the throttle washer must be removed from the fan outlet.

Horizontal sections of the pipeline must be installed with a slope of at least 1.5% towards the outlet flue gases so that condensate flows out of the pipeline. In vertical sections, condensate drainage devices are used.

The pipeline outlet should be located:

At a height of at least 2 m from the foundation of the building in places visited by people and at least 0.4 m in places not visited by people;

At a distance of at least 0.5 m horizontally from windows that are constantly open ventilation grilles and doors;

Above the top border of windows, bars or doors;

In the area under awnings, balconies and roof edges.

Minimum distance between two adjacent pipeline outlets:

Horizontal – 1 m;
- vertically – 2 m.

The direction of the pipe exit should be oriented so that combustion products exit into open space.

The horizontal distance from the end of the pipeline outlet on one facade to the other, with opposite placement of outlets, should be:

2 m, if there are no windows or grilles on one facade;

1 m if both facades are without windows or bars;

4 m if both facades have windows or bars (or if there are adjacent exits on the same facade).

In the niche of the building facade, the distance between the axis of the pipeline outlet and the adjacent plane of the facade should be:

2 m if there are windows or bars on the facade;
- 0.5 m - if they are absent.

All distances are given from the outer boundary of the window (grid) or door to the axis of the pipeline. In the space under the canopy (balcony), the head of the pipe must be at a distance of at least the radius of the circle.

When pipelines exit vertically onto the roof, their heads must be placed at a distance of at least 0.4 m horizontally and at a height of at least 0.4 m from the roof surface, taking into account its shape.

The chimney outlet must not be located in an explosive area, internal parts buildings or structures, tunnels or underground passages, in closed spaces.

The hole in the wall for the passage of the coaxial pipeline is made with a certain gap (from 10 to 15 mm). Upon completion of installation, the gap is insulated with non-combustible materials ( polyurethane foam, gypsum, plaster).

Electrical connection of the gas boiler Proterm Panther

The Proterm Panther boiler must be connected to the electrical network through a plug socket with a grounding contact, which eliminates the “zero-phase” connection error. The distance from the boiler to the socket must be within the length of the boiler power cord (1 m).

The boiler must be connected to a protective conductor (grounding). The grounding conductor must be accessible for inspection and resistance testing.

For electrical connection It is not allowed to use various tees, extensions, etc. The boiler is protected from overload and short circuit by fuses P1 – T80 mA/250V, P2 – T 1.6 A/250V, installed in the control panel. Before working with the electrical equipment of the boiler, it is necessary to disconnect the boiler from the network by disconnecting the electrical plug from the socket.

To control the boiler from a room regulator, use a regulator with a potential-free output (other than the mains voltage, no other voltage is allowed to be supplied to the boiler). Connect the room regulator to the unit with a flexible two-core cable with a cross-section of 0.5 to 1.5 mm2. Exit the cable from the boiler through a plastic cable sleeve.

The terminal block for connecting the room regulator and external sensor is located at the bottom, inside the boiler and is accessible after removing the outer cover and turning the control panel. Before connecting, the jumper must be removed from the terminal block. The minimum load of the regulator output contacts is 24 V / 0.1A.

The outside temperature sensor should be connected with a two-core copper conductor with a cross-section of 0.75 mm2. Wiring resistance should be no more than 10 ohms, maximum length- 30 m.

The circuits for connecting the outside temperature sensor and the room regulator must not be laid together with the mains voltage circuits.

Work on putting the Protherm Panther boiler into operation:

Remove the screw securing the lid at the bottom of the boiler;

Tilt the cover down (toward you) and lift it off the pins at the top of the camera.

Make sure the gas supply is turned off.

Loosen the cap on the automatic air separator located on the pump.

Connect the boiler to the electrical network.

Translate power switch to position “I”. The display will show code F0 and the pump will run for approximately 1 minute.

Press the Bar/Mode button. The display will show 0.0 (pressure value) and the LED will light up.

The pressure value is displayed for about 25 seconds. After this, the display returns to its original position. The pressure value can be displayed again by pressing the Bar/Mode button.

Fill the system with water, the pressure should be between 1.2 and 2 bar.

Carefully release the air from all heating devices (the flow of water should be continuous, without air bubbles).

Leave the cap on the air separator loose while the boiler is operating.

Open the DHW taps to remove air from the DHW circuit;

Make sure that the pressure shown on the display is in the range of 1.2 - 2 Bar, top up if necessary.

Starting the Proterm Panther boiler

Before starting the boiler, check:

The main gas supply valve is open,
- gas tap open at the entrance,
- closing valves (water, heating) at the outlet are open,
- the unit is connected to the electrical network.

To start the Protherm Panther boiler, do the following:

Switch the power switch to position “I”;

Set the extract air temperature to 85 °C and switch off the equithermal control (E-).

Check the condition of the room regulator (it must be closed);

Smoothly raise the temperature in the heating system to maximum (all radiators should have open valves). The air in the water of the heating system is gradually removed through an automatic air separator. There should be no air at the highest point of the system and in the radiators;

Make up the system to a pressure of 1.2 Bar;

Turn on the boiler again and heat the system to maximum temperature;

Turn off the boiler, remove air if necessary and refill the system with water;

Make sure that after the heating system has cooled down, the pressure gauge shows at least 1.2 Bar;

If the pressure in the heating system in the heated state is higher by. 0.5 bar than when cold, check the setting of the expansion tank relative to the system.

Protective functions of the Proterm Panther boiler

The boiler is equipped with a frost protection function. When the temperature drops below 10 °C, the pump will automatically turn on. When the temperature drops below 8 °C, the device will ignite and operate until the temperature rises by 25 °C. If it freezes (exhaust temperature below 3 °C), the boiler start-up is blocked.

Pump on a short time turns on automatically if it has not been turned on for 24 hours. This ensures protection against blocking due to deposits during prolonged shutdown. The pump operates continuously when the temperature rises above 85°C (overheat protection).

When the pressure drops, the LED flashes; when the pressure drops further, the unit goes out (protection against water loss - alarm F0). When the pressure increases, operation automatically resumes.

The protective functions are only activated when the boiler is connected to mains voltage ( electrical cord is in the socket, and the power switch is in the on position (I).

If the boiler has been disconnected from the mains voltage for a long time (a month or more), it is recommended to start it periodically (at least once a month). The boiler is equipped with a safety valve. When discharging heating water from the valve, turn off the boiler and disconnect it from the mains voltage.

Adjusting the Protherm Panther boiler

When the boiler operates without a room regulator, it maintains the temperature set on the display.

Adjustment operations:

– select the equithermal regulation mode – select the heating curve and set the E- symbol;

– select the equithermal regulation mode – in the parallel movement option put the symbol P-;

– select the Exhaust temperature mode and configure it;

– the room regulator must be turned off, and a jumper must be installed between the terminals to connect it.

When the Proterm Panther boiler operates with a room regulator, it maintains the temperature set on the display. In this case, the unit is turned off according to the commands of the room thermostat installed inside the control room. There should be no thermostatic valve on the radiator in this room.

During installation, the jumper is removed from the boiler terminals and the room thermostat is connected. When operating in equithermal mode, the temperature changes depending on the change in outside air temperature.

An outside air temperature sensor must be connected to the boiler. The sensor is installed on the cold wall building (north or north-west) at a height of about 2.5 - 3 m. The sensor should not be located in the area of ​​​​ventilation emissions from windows or other ventilation devices
and be exposed to direct sunlight.

Inlet gas pressure control:

Turn off the boiler.

Loosen the screw on the pressure measuring fitting of the gas valve;

Connect the appropriate pressure meter;

Carry out a launch;

Check the gas inlet pressure, if it is below normal, check the tightness of the gas pipeline;

Turn off the unit and disconnect the pressure meter, carefully tighten the screw on the measuring fitting and check its tightness.

When purchasing any heating equipment the user receives instructions. It describes all the points that relate not only to the installation of the unit, but also to its operation. The Proterm Skat 9 kW boiler is no exception. Of course, for some reason the instructions were lost, then it will not be possible to start heating the house. After all, an electric boiler needs to be configured correctly. Exist certain rules installation and operation of the electrical unit. They must be respected. Otherwise, the equipment will not work correctly.

The advantage of the electric boiler Proter Skat

The Proterm Skat unit has a number of advantages. Such heating equipment has become a good alternative to gas heating devices. The popularity of Proterm Skat boilers is increasing every year. After all, such units are ideal for heating houses that are not connected to the main gas pipeline. Electric boilers of this modification are simply indispensable for country cottages with periodic or seasonal residence.

Among the advantages of such units, the following should be highlighted:

It is worth noting that Proterm Skat electric boilers have proven themselves to be economical and safe heating devices during their existence.

Installation Features

Proterm Skat 9 kW boilers are supplied with all necessary fasteners and elements. Besides The kit includes instructions that describe the process of connecting and setting up the unit step by step. It is worth noting that models that differ in power have exactly the same principles of installation, operation, and configuration.

Before installing Proterm Skat heating equipment, it is necessary to coordinate all work with electrical distribution services.

Proterm Skat electric boilers with a power of 9 kW can be connected to a conventional 220V electrical network. Installation of such heating equipment is carried out using fastening strip. Such a unit has no certain restrictions on the choice of installation location. Of course, there are some requirements - you need free access for service, maintenance, adjustment and repair of heating equipment.

How to install

The Proterm Skat electric boiler is connected to the pipe system using pipes. Connection heating device is carried out so that if a malfunction occurs during operation, the coolant can be easily drained without affecting the entire system. Additional valves allow you to fill the system with coolant and drain it. Also, in order to prevent freezing of water in houses with seasonal residence during cold periods, experts recommend removing the coolant completely from the system before temperatures drop.

The Proterm Skat boiler is connected to the electrical network through a power line supplied separately. Connects network cable to the terminals, which are located in the lower corner of the housing. All screws on the connectors must be carefully tightened. A boiler with a power of 9 kW can be connected to a single-phase network.

How to use the Proterm Skat boiler

The process of operating the Proterm Skat electric boiler does not cause any particular difficulties. After all, something like this heating equipment is equipped with systems for control and regulation. For the device to start working, you need to do just a few simple steps:

  1. Connect the unit to the power supply.
  2. Select the required temperature mode on the heating equipment control panel.
  3. Adjust the power of the unit.
  4. Make more precise adjustments temperature regime.
  5. If necessary, change the pressure level in the system.

After the completed manipulations, you must press the “Start” button. That's it, the Proterm Skat boiler is ready for use. During the first few days of operation, it is worth monitoring the operation of the unit and, if necessary, adjusting the temperature regime. This will identify some problems in the operation of the unit caused by the presence of air pockets in the system.

if you have Vacation home, and communications are not connected to it, then you can solve the issue expressed in the need for heating and providing water heating with the help of boiler equipment. The main thing is to do right choice, because such an installation will occupy a central place in the house and heating system. The choice should be made based on safety and reliability rules.

Modern heating equipment is offered in a huge range. You may prefer floor standing or wall model, with or without a chimney, non-volatile or powered. Modern manufacturers offer single-circuit and double-circuit heating equipment for sale. The former will be able to make the house more comfortable and cozy, while the latter will allow you to use hot water. Before making a choice, you need to read the reviews; Proterm boilers are no exception to this rule. They are offered in a wide range, can have different power and specifications, you can read about this below.

Review of boilers from the manufacturer "Proterm": "Bear 50 KLZ"

This equipment model costs RUB 143,914. It is a gas floor-standing boiler that can operate on mains fuel. The consumer will have the opportunity to provide a connection to liquefied gas. The equipment is double-circuit and is used for heating, as well as for hot water supply. The design has open camera combustion.

To remove combustion products, a fan must be connected. This Proterm Bear boiler has a 10-liter expansion tank. The heat exchanger is based on cast iron, which increases the reliability and service life of the boiler. The manufacturer made sure that the unit was protected from overheating of the coolant in the system. To do this, engineers equipped the model with a cooling circuit. Convenient start-up of the device is ensured by electric ignition.

Considering the model of heating equipment “Bear 50 KLZ”, we can mention that it has a power of 49 kW. The burner is modulating. The maximum power consumption is 50 kW. Gas temperature at minimum and maximum power equal to 115°C.

You may also be interested in how liquefied gas is consumed; the value is 3.8 kg per hour. Heating temperature is equivalent to 85°C. At 25°C coolant, productivity reaches 21 liters per minute. If the dimensions of the boiler room are limited, then you should take an interest in the design parameters, they are 1385x505x892 mm. The device weighs 210 kg. It belongs to the X4D protection class. The volume of the expansion tank is 10 l.

The coolant outlet temperature can reach up to 70 °C. Possible pressure natural gas equals 0.013 bar. Maximum natural gas consumption 35.2 m 3 /h. If you plan to connect the equipment yourself, then you may need a chimney diameter of 180 mm. At 100% thermal power, the equipment efficiency is 92%.

Reviews about the model

The above-described Proterm heating boiler, according to consumers, has many positive features, among them the following should be highlighted:

  • simple controls;
  • high efficiency;
  • independent regulation of thermal loads;
  • possibility of replacing middle cast iron sections.

As for ease of control, it is provided by an external panel with which you can adjust and control the parameters of the floor-standing model. Consumers emphasize that this equipment is used for systems with closed circulation coolant.

The device is controlled using a built-in microprocessor. Buyers, in their words, quite often choose this model for the reason that it provides the ability to independently adjust the thermal loads of the hot water supply and heating circuits. The unit is also good because it is resistant to complex hydraulic conditions.

User manual

After you familiarize yourself with the characteristics of the Proterm boiler that you have purchased or are just planning to purchase, it would not be a bad idea to ask what operating rules the manufacturer prescribes. Quite often, this allows you to extend the life of the equipment or prevent its breakdown. As for the model described above, it must be installed only in specially equipped rooms for this purpose.

The device is put into operation only after testing. It is important to follow safety regulations. They say that gas supply standards must be taken into account. You can set the water temperature in the boiler yourself. This also applies to heating temperature. In this case, the operator will have to use the MODE button.

To set the time intervals for heating water in the boiler, use a timer. The operation of the Proterm gas boiler is also convenient because on the panel you can see equipment messages about errors that occur during operation. For example, if you see an F1 code, it will indicate a loss of flame. But the designation F2 indicates that the boiler temperature sensor was faulty.

Review of the wall-mounted boiler brand "Gepard 23 MTV"

Another equipment option from the manufacturer Proterm is Gepard 23 MTV. You can purchase this model for RUB 42,088. The device was developed in 2015 and is used for heating as well as hot water supply.

The design provides for a closed combustion chamber, which makes it possible to use a coaxial chimney. The boiler has a primary heat exchanger made of copper. The burner is made of chromium-nickel steel. The heat exchanger in the device is plate-type, it is made of of stainless steel.

Specifications

The above-described Proterm Cheetah boiler has a power of 24.6 kW. Power consumption reaches 156 W. Buyers are often interested in the maximum consumption of natural gas, which is 2.9 m 3 /h. Temperature hot water at the outlet can reach 65°C, while its minimum value equals 35 °C. The permissible natural gas pressure is 0.02 bar. The volume of the expansion tank is 5 liters.

The equipment belongs to the X4D protection class. The unit weighs 34 kg, this should be taken into account, because the Proterm wall-mounted boiler must be securely mounted on a vertical surface. The flue gas temperature is 110°C. Maximum fuel consumption when used liquefied gas- 2.1 kg per hour. The heating temperature can reach 83°C, while the minimum value is 35°C. If you plan to install the device in cramped conditions, then you should be especially interested in the dimensions of the unit; they are 740x310x410 mm.

Among the main advantages of the above-described equipment option, consumers highlight:

  • closed combustion chamber;
  • equipped with a coaxial exhaust gas system;
  • the ability to receive information about the operation of the boiler using a liquid crystal display;
  • automatic switching to hot water supply mode when opening a hot water tap.

If we compare this model with the previous one in the line, it was equipped by the manufacturer with a display. Its bright backlight allows the user to see data even in a bright room. The boiler is durable and reliable, which is ensured by a hydraulic block made of composite material. This feature improved the model compared to the previous generation, where the units were equipped with hydraulic units.

User manual

Instructions for the Proterm boiler are included. This is very convenient, because immediately after purchase you can familiarize yourself with it in order to avoid mistakes when using the device. If the boiler is not used for its intended purpose, this may pose a danger to human health and life. If during operation of the equipment you notice strong smell gas, you should open the doors and windows wide, creating a draft. Do not use open flames or smoke, or turn on plugs, telephones or other intercoms in the building.

Do not store or use explosive or flammable substances such as paper, gasoline and paint in the same room as the boiler. Sufficient air supply must be provided for combustion. Protective devices There is no need to remove or shunt the equipment during operation. WITH protective systems It is not recommended to perform any manipulations.

Review of the Panther 35 kW boiler

This Proterm gas boiler has an affordable price of 63,398 rubles. The equipment is a two-circuit unit with closed camera combustion. The device includes a primary heat exchanger and plate heat exchanger hot water supply, which is made of stainless steel. The liquid crystal display is located on the external panel, which allows the operator to see the data even in a bright room. The risk of freezing is reduced, as is overheating thanks to additional elements security.

Model specifications

After reading the reviews about Proterm boilers, you can understand which model is better to choose. But it is also important to take into account the technical characteristics. For example, the Panther model has a power of 35 kW. Power consumption reaches 175 watts. The flue gas temperature at minimum power is 102.9°C. This traditional boiler provides a maximum power consumption of 38.4 kW.

Electric boiler Proterm A heating ramp is the most common model in Russia among all manufacturers represented on the domestic market. Good quality European assembly and reliability of components, many positive reviews on electrical Protherm boilers and reasonable prices contributed to their popularity among buyers, both in Russia and abroad.

To understand the advantages and disadvantages of Slovak heating equipment, it is necessary to analyze the technical characteristics and design of wall-mounted electric boilers of the Proterm Skat series, the lineup, presented on the market, and connection features. We will also consider problems and malfunctions that may arise during operation of the device, errors and methods for eliminating them.

Model range of electric boilers Proterm Skat, type K(KR)

Today, the Slovak company Protherm is represented on Russian market not only with its boilers, but also with eight models of electric boilers of the Skat K(KR) type, differing in power consumption and connection to the electrical network. The country of origin of water heaters is Slovakia.

The company produces only single-circuit devices capable of heating a private house with total area from 30 to 280 m2. Among them, both single-phase ones stand out - with the ability to connect to a 220 V power supply network, and three-phase ones - 380 Volts.

Electric boiler Proterm: photo


The main difference between electric boilers of this model range is their rated power, which can be 6 or 9 kW, 12, 14 or 18 kW, 24 and 28 kW. Depending on the chosen model, these are the units:

low power: Scat 6K and 9K;
- medium power: Scat 12K, 14K and 18K;
— high power: Skat 21K, 24K and 28K.

The operation of the Proterm electric boiler is controlled using special buttons, made in the form of multi-directional arrows, on the front panel of the heating apparatus.

They can set the required water temperature in the heating system, as well as in the remote boiler indirect heating, which is purchased when it is necessary to obtain hot water for household needs. In addition, the button " Mode/Ok» you can turn on (set) the desired operating mode of the electric boiler:

— traditional mode for heating (25-85 °C);
— “warm floor” mode (30-45 °C);
— hot water preparation mode in an indirect heating boiler (35-70 °C).

The multifunctional LCD display informs about the temperature in the heating circuit and the boiler, as well as about problems and errors in the operation of the boiler in case of any malfunctions. Above the display there are lights that light up depending on the set operating mode of the device, changes in power consumption and insufficient water pressure in the system.

By default, all Protherm electric boilers are 3-phase, however, low-power models of 6 and 9 kW (“Skat 6K” and “Skat 9K”) can be connected to a single-phase 220 V network. Medium power devices are designed for heating houses with an area of ​​up to 180 m2, and high-power boilers - more than 20 kW can be installed in private houses or other premises with a total area of ​​up to 280-300 m2. Let's look at the table.

Proterm Skat: cable cross-section, energy consumption


Features of the Proterm electric boiler

The heating apparatus consists of several main elements necessary for its full operation.

1. Cylindrical copper heat exchanger for heating the coolant.
2. Block of heating elements made of copper of different power and quantity with multi-stage switching.
3. Expansion tank 7 liters to compensate for thermal expansion in the heating system.
4. Hydraulic group consisting of:

- three-speed circulation pump ;
— safety valve at 3 bar;
— automatic air vent.

Also on line heating circuit An NTS temperature sensor is installed, as well as an emergency sensor that protects the unit from overheating. There is a system to protect the device from freezing. and from blocking the circulation pump.

Electric heating elements are built into the heat exchanger of the Proterm boiler, top and bottom. Depending on the model, the number of heating elements may vary. For example, in Skat 6K, 9K, 12K and 14K devices two heating elements are installed, in Skat 18K and 21K there are three heating elements, in 24K and 28K there are four. For each model, heating element blocks have different power.

I propose to analyze in detail internal organization mounted electric boiler "Proterm Skat" according to the instruction diagram:

Internal device "Protherm Skat" according to instructions


1 - heating unit;
2 - valve for air release;
3 - heat exchanger;
4 - pressure sensor;
5 - safety valve;
6 — circulation pump adjustment regulator;
7 — pump status LED;
8 — grounding on the “return”;
9 — grounding on the water heater body;
10 - circulation pump;
11 - electrical cable connection;
12 - contactor;
13 - electronic board;
14 - NTS temperature sensor;
15 - emergency temperature limiter sensor.

Electric boiler connection: water circuit, cable

Connecting a Protherm electric boiler


1. Like most modern wall-mounted heating devices, all connectors for connecting the boiler are located at the bottom of the housing. This is done to save space in the room in which the electric boiler is installed.

2. The heating water circuit is connected using two threaded fittings with a diameter of 3/4″. On the left is the return line (coolant inlet to the boiler), on the right is the direct line (output).

3. Nearby are located: overflow for the safety valve, drain valve, as well as connectors for connection electric cable different sections. You can monitor the pressure in the heating system using the readings of the pressure gauge, which is also located in the lower part of the device body.

Electric boilers Proterm Skat: technical characteristics, dimensions

Proterm boilers have fairly compact dimensions of 410 x 740 x 310 mm, which allows them to fit harmoniously into the interior even completely small kitchen or boiler room. We look at the remaining technical characteristics in the table.

Technical characteristics of Proterm electric boilers


Errors and malfunctions of the Proterm electric boiler: methods for troubleshooting problems

1. Error code F00, F10, F13, F19.

These codes tell us that the NTS temperature sensor is faulty. It may need to be replaced or the electronic board replaced. But first check that the cable connections are working properly.

2. Error F20.

The emergency temperature limiter sensor or thermal fuse is faulty. Try to short-circuit them one by one. If the boiler turns off again, replace the faulty element.

3. Error F22.

This error indicates a “dry” start of the electric boiler. Add water pressure in the system, it should be at least 0.6 Bar. There may also be air present in pipes and radiators.

4. Error code F41 and F55. The relay or contactor is stuck. Check these parts for defects.

5. Error F63. No communication with EEPROM. Reset settings to factory defaults.

6. Errors F73 and F74.

Errors under these codes indicate problems with the water pressure sensor. You need to check the contacts or replace the sensor itself.

7. Errors F85 and F86. Freezing of water in the electric boiler itself (F85) or in the indirect heating boiler (F86).

Electrical diagram for connecting Proterm Skat boilers

Electrical diagram for connecting the boiler Proterm Skat 6, 9, 12, 14K


Advantages of Proterm electric boilers:

— build quality and operational reliability;
— wide range of different capacities;
modern system security;
— high efficiency 99.5%;
— the ability to connect additional options and equipment;
good feedback buyers and specialists.

Disadvantages of the Proterm brand electric boiler:

— lack of a room unit included in the package;
— there are no models with a built-in boiler for heating domestic water;
— the use of non-freezing liquid as a coolant is not permitted;
— price from 35,000 rubles.

We looked in detail electric boilers Proterm Heating ramp, entire model range and technical specifications. Having disassembled the internal structure according to the operating instructions, we identified the main advantages and disadvantages of these devices. We also focused on possible errors if malfunctions occur and some ways to fix them yourself. Let's watch the video.